TEST REPORT |
|
|
|
|
DATE OF REPORT
|
: 22 AUGUST 2001 |
|
REFERENCE NUMBER
|
:
01-4865.08-002 |
|
CONTACT PERSON
|
: LLOYD
ASKHAM |
|
NAME OF COMPANY
|
: POLTECH
(PTY) LTD |
|
ADDRESS OF COMPANY
|
: P. O. BOX
7211 |
|
|
: CENTURION |
|
|
: 0046 |
|
CONTACT PERSONS
|
: DIETHARD
MATHY |
|
CLIENT
|
: CONVEYOR
AND PIPING SYSTEMS |
|
ADDRESS
|
: 248
MIMOSA ROAD |
|
|
:
NORTHCLIFF |
|
|
:
JOHANNESBURG |
|
|
: 2195 |
|
|
|
|
CLIENT FAX NUMBER
|
: (011)
678-5312 |
|
CLIENT TELEPHONE NUMBER
|
: (011)
478-1270 |
|
|
|
|
1.0
|
PURPOSE
|
|
|
The
purpose of this survey is to reflect the findings of a Conveyor System
Noise Level survey conducted on the 17 August 2001 at PORTNET Richards
Bay. |
|
2.0
|
INTRODUCTION
|
|
|
Conveyor and Piping Systems
cc produce conveyor systems utilising work rolls composed of two different
material; i.e. Steel-based and Titanium-enriched Polyvinyl Chloride
based. Besides the increased strength offered by titanium, the
product is resistant to Ultra-violet radiation and is anti-static.
This makes it ideal for use in environments where static charge is
forbidden. There is also speculation that the Titanium-enriched PVC
should produce lower noise levels during operation as compared to the
conventional Steel-based rolls.
Mr. Diethard
Mathy, on behalf of
Conveyor and Piping Systems cc, requested POLYTECH (PTY) LTD to conduct an
investigation to compare the noise levels produced by both systems during
operation at PORTNET, Richards Bay. Subsequently, a consultant from
POLYTECH (PTY) LTD visited the site during 17 August 2001, to perform the
applicable noise level measurements. |
|
3.0
|
HEALTH HAZARDS ASSOCIATED
WITH EXPOSURE TO NOISE
|
|
|
Noise or unwanted sound is
one of the most widely and frequently experienced problems of the
industrial working environment. It can annoy, interfere with
communication, cause fatigue, and reduce work efficiency. Of major
concern, however is that intense noise or long periods in a noisy
environment can cause a permanent reduction of hearing sensitivity through
damage to the sensory organs of the inner ear. This type of noise
induced hearing damage or loss can seriously affect speech recognition and
may be irreparable.
The risk of hearing damage escalates
with increasing levels and time period of noise exposure. It also
depends on the characteristic of the offending sound, such as its
frequency and whether it is impulsive or continuous. In addition,
some individuals are more susceptible to the harmful effects of noise than
others. |
|
4.0
|
SURVEY METHODOLOGY
|
|
|
The Method followed during
this survey is described in SABS 083:1996. "The Measurement and
Assessment of Occupational Noise for Hearing Conservation
Purposes". The noise level was measured by means of a Quest,
Type 1 (IBC spec. 651/804, Model 1800 impulse, precision integrating sound
level meter, calibrated before and checked after measurements, with a
Quest CA22 (IEC spec. 942) sound level calibrator. No background noise
correction were made as the differnce between the measured signal and any
background influences was greater than 10dB.
|
|
5.0
|
RESULTS
|
|
|
The results of the Noise
Level Measurements performed at PORTNET Richards Bay on 17 August 2001 ate
indicated in table 5.1
|
TABLE 5.1:
CONVEYOR SYSTEM NOISE MEASUREMENT RESULTS CONDUCTED AT PORTNET RICHARDS
BAY, 17 AUGUST 2001
|
|
Work
Roll
Type |
Position/Location
(1
metre from conveyor belt) |
Noise
Level
dB(A) |
Comments |
| Steel-based |
N2
Conveyor |
79.0# |
No Load. Measurement
approximately 90m from N2 drive motor. |
|
Titanium-enriched
PVC |
K24
Conveyor |
75.5# |
No
Load. Measurement approximately 100m from Plough. No significant
additional noise sources. |
|
Note:
|
|
|
dB(A)
|
=
Decibel, A band frequency
|
|
*
|
= Noise
level equal to or exceeding the South African statutory limit of 85dB(A)
(thus excessive)
|
|
#
|
= Same
circumstance noise levels, for the basis of comparison
|

|